Downloads :      Leaflet   |   Manual
 
   
   
   
 



MICROTEK - Eb RANGE OF PRODUCTS

MICROTEK UPS EB models are designed using latest state-of-the-art Technology for Better Performance & High Reliability.
  • MICRO-CONTROLLER BASED Intelligent Control Design.
  • Display Indications (Status & Fault)
  • CCCV Technology with Auto Trickle Mode
  • Smart Overload Sense and Short Circuit Protection
  • Battery State Monitoring
  • Easily Serviceable
  • Multi Stage Battery Charger
  • Mains Input Voltage Range Selection
Technical Specification
Model
EB - Offline Series
Capacity
400 VA, 600 VA, 850 VA, 860 VA, 1000 VA, 1500 VA, 2000 VA
Battery
400/ 600/ 850/860/1000-1Battery System
1500/2000-2Battery System
Input Voltage
100V~300V (Wide input voltage range)
180V~260V (Normal input voltage range)
Output Voltage on Mains Mode
Same as Input
Output Voltage on UPS Mode
200V~230V ± 10%
Output frequency on UPS Mode
50 Hz ± 0.1 Hz
Switching from Mains to UPS
Automatic
from UPS to Mains
Automatic
Output Waveform on Mains Mode
Same as Input
Output Waveform on UPS Mode
TPZi Waveform (TRAPE ZOIDAL WAVEFORM)
Battery Charging Current
Constant Charging Approx 10% of The Rated Battery Current in AH
Charger
Constant current, Constant wattage
Efficiency
> 84%
UPS Overload
120%
UPS Short Circuit
300%
UPS Transfer Time
≤ 15 msec.
Browns out Mains Voltage
100V ± 40V
Technology
MICRO CONTROLLER BASED DESIGN
Auto Reset Feature
Yes
Charger current
UPS EB 400 : 4~5A
UPS EB 600 : 9~10A
UPS EB 850/860 : 9~10A
UPS EB 1000 : 12A
UPS EB 1500 : 10A
UPS EB 2000 : 12A

MICROTEK - E² ENERGY SAVER RANGE OF PRODUCTS

  • MICRO-CONTROLLER BASED, Intelligent Control Design.
  • Highly Efficient Transformer, which helps in Fast charging of the battery, Increases the Backup and Saves Energy.
  • Minimum Energy loss while conversion from DC to AC.
  • Display Indications (Status & Fault)
  • CCCV Technology with Auto Trickle Mode
  • Smart Overload Sense and Short Circuit Protection
  • Battery State Monitoring
  • Easily Serviceable
  • Multi Stage Digital Battery Charger
  • Mains Input Voltage Range Selection

Microtek E2 products use Hi-Grade Low Watt Loss Silicon Steel Core in Transformers with a Watt Loss of approx 3.6W to 4W, whereas the other manufacturers are using core having Watt loss of approx 7W to 10W. Thereby Other products have additional power consumption equivalent to 15W to 35W per hour continuously from 625 to 1550 respectively.

In Microtek you save on this Watt loss, and in terms of Money, it leads to a saving of Rs 60/- to Rs 140/- per month for the end user for 625 to 1550 respectively

Examples of Savings
Other Energy Efficient Features:

ZPS Technology : India's First Energy Efficient, E2 UPS / Inverter with ZERO POWER SWITCHING - Ensures ZERO SWITCHING LOSES OF ENERGY at conversion level from DC to AC. Unlike other products where lot of energy is lost in this process.

DFLC Technology : India's First Energy Efficient E2 UPS / Inverter with DIGITAL FUZZY LOGIC CHARGING - Judges the condition of the battery and sets charging voltage & Charging current as per requirement, while conversion from AC to DC. Thus saves energy while charging battery.

HI-GRADE VIRGIN Copper Wire used in transformers delivers longer life with low temperature rise.

Intelligent Thermal Management for longer life and high reliability.

15% More load Carrying capacity than similar models of other manufacturers.

Technical Specification
Model
E² - Offline Series
Capacity
400 VA, 625 VA, 875 VA, 1025 VA, 1550 VA
Battery

400/625/875/1025 - 1 Battery System
1550 - 2 Battery System

Input Voltage
100V 300V (Wide input voltage range) 
180V~260V (Normal input voltage range)
Output Voltage on Mains Mode
Same as Input
Output Voltage on UPS Mode
200V~230V 10%
Output frequency on UPS Mode
50 Hz 0.1 Hz
Switching from Mains to UPS and from UPS to Mains
Automatic
Output Waveform on Mains Mode
Same as Input
Output Waveform on UPS Mode
TPZi Waveform (TRAPE ZOIDAL WAVEFORM)
Battery Charging Current
Constant Charging Approx 10% of The Rated Battery Current in AH
Charger
Constant Current, Constant Wattage
Efficiency
> 87%
UPS Overload
120%
UPS Short Circuit
300%
UPS Transfer Time
= 15 msec.
Browns out Mains Voltage
100V 40V
Technology
MICRO CONTROLLER / DSP BASED DESIGN
Auto Reset Feature
Yes
Auto Reset Feature
Yes
Charger current
UPS E2 400 - 4 A
UPS E2 625 - 6.75 A
UPS E2 875 - 10 A
UPS E2 1025 - 10 A
UPS E2 1550 - 10 A