MICROtek SEB - Online Series |
MICRO CONTROLLER / DSP BASED DIGITAL SINEWAVE UPS EB are designed using latest state-of-the-art Technology for Better Performance and High Reliability. The Digital Sinewave Technology used enhances the life of the battery and minimum effort has to be put for maintenance.
- MICRO-CONTROLLER / DSP BASED
Intelligent Control Design.
- MICRO-CONTROLLER / DSP BASED
Intelligent Control Design.
- Pure Sine Wave Output.
- PWM Controlled multistage ATM
(Automatic Trickle Mode) Charging
- Display Indications (Status &
Fault)
- Smart Overload Sense and Short
Circuit Protectio
- Easily Serviceable
- Auto Reset Feature
- Mains Input
Voltage Range
Selection.
|
|
Technical Specification |
| Model |
SEB
- Online Series |
| Capacity |
850 VA,
1500 VA, 2200 VA |
| Input Voltage |
100V~300V (Wide
input voltage range)
180V~260V (Normal input voltage
range) |
| Output Voltage on Mains Mode |
Same as Input |
| Output Voltage on UPS Mode |
210V ± 5% |
| Output frequency on UPS Mode |
50 Hz ± 0.1 Hz |
| Switching from Mains to UPS |
Automatic |
| from UPS to Mains |
Automatic |
| Output Waveform on Mains Mode |
Same as Input |
| Output Waveform on UPS Mode |
Pure Sine Wave |
| Battery Charging Current |
Constant Charging
Approx 10% of The Rated Battery Current in
AH |
| Charger |
Power Factor
Controlled Boost Technology |
| Efficiency |
> 80% |
| UPS Overload |
120% |
| UPS Short Circuit |
300% |
| UPS Transfer Time |
≤ 15 msec. |
| Browns out Mains Voltage |
100V ± 40V |
| Technology |
MICRO CONTROLLER
/ DSP BASED DESIGN |
| Auto Reset Feature |
Yes |
|
MICROTEK - E² ENERGY SAVER RANGE OF PRODUCTS |
- MICRO-CONTROLLER BASED, Intelligent Control Design.
- Highly Efficient Transformer, which helps in Fast charging of the battery, Increases the Backup and Saves Energy.
- Minimum Energy loss while conversion from DC to AC.
- Display Indications (Status & Fault)
- CCCV Technology with Auto Trickle Mode
- Smart Overload Sense and Short Circuit Protection
- Battery State Monitoring
- Easily Serviceable
- Multi Stage Digital Battery Charger
- Mains Input Voltage Range Selection
|
|
Microtek E2 products use Hi-Grade Low Watt Loss Silicon Steel Core in Transformers with a Watt Loss of approx 3.6W to 4W, whereas the other manufacturers are using core having Watt loss of approx 7W to 10W. Thereby Other products have additional power consumption equivalent to 15W to 35W per hour continuously from 625 to 1550 respectively.
In Microtek you save on this Watt loss, and in terms of Money, it leads to a saving of Rs 60/- to Rs 140/- per month for the end user for 625 to 1550 respectively
|
Examples of Savings |
 |
Other Energy Efficient Features: |
ZPS Technology : India's First Energy Efficient, E2 UPS / Inverter with ZERO POWER SWITCHING - Ensures ZERO SWITCHING LOSES OF ENERGY at conversion level from DC to AC. Unlike other products where lot of energy is lost in this process.
DFLC Technology : India's First Energy Efficient E2 UPS / Inverter with DIGITAL FUZZY LOGIC CHARGING - Judges the condition of the battery and sets charging voltage & Charging current as per requirement, while conversion from AC to DC. Thus saves energy while charging battery.
HI-GRADE VIRGIN Copper Wire used in transformers delivers longer life with low temperature rise.
Intelligent Thermal Management for longer life and high reliability.
15% More load Carrying capacity than similar models of other manufacturers.
|
Technical Specification |
Model |
E² - Online Series |
| Capacity |
625 VA, 875 VA, 1550 VA |
| Battery |
625/875 - 1 Battery System
1550 - 2 Battery System |
| Input Voltage |
100V~300V (Wide input voltage range) |
180V~260V (Normal input voltage range) |
| Output Voltage on Mains Mode |
Same as Input |
| Output Voltage on UPS Mode |
210V ± 5% |
| Output frequency on UPS Mode |
50 Hz ± 0.1 Hz |
| Switching from Mains to UPS and from UPS to Mains |
Automatic |
| Output Waveform on Mains Mode |
Same as Input |
| Output Waveform on UPS Mode |
PURE SINE WAVE |
| Battery Charging Current |
Constant Charging Approx 10% of The Rated Battery Current in AH |
| Charger |
Power Factor Controlled Boost Technology |
| Efficiency |
> 83% |
| UPS Overload |
120% |
| UPS Short Circuit |
300% |
| UPS Transfer Time |
= 15 msec. |
| Browns out Mains Voltage |
100V ± 40V |
| Technology |
MICRO CONTROLLER / DSP BASED DESIGN |
| Auto Reset Feature |
Yes |
| Charger current |
UPS SWE2 625 - 6.75 A |
UPS SWE2 875 - 10 A |
UPS SWE2 1550 - 10 A |
|